Emon Meter Wiring Diagram


Emon Meter Wiring Diagram

At present you are looking regarding an Emon Meter Wiring Diagram example of which we provide here inside some kind of document formats such as PDF, Doc, Strength Point, as well as images of which will make it easier for you to create an Emon Meter Wiring Diagram yourself. For a better look, you are able to open some examples below. Each of the illustrations about Emon Meter Wiring Diagram with this site, we get from several sources so you can create a better file of your own. If the search you obtain here does not match what you are seeking for, please utilize the lookup feature that we have got provided here. You will be free to download something that we provide right here, it will not cost you the particular slightest.

INSTALLATION OVERVIEW INSTALLATION DIAGRAM

SINGLE-PHASE, 3-WIRE 120/240, 120/208 or 480 VOLT INSTALLATION DIAGRAM 1-PHASE, 2-WIRE 120 or 277 VOLT INSTALLATION DIAGRAM (Class 1000 Series Only) *** * These terminals are not used in Class 1000 installations. LINE VOLTAGE CURRENT SENSORS ∅A ∅B ∅C ∅ W B W B W B A ∅B ∅C N *

Emon Demon Wiring Diagram

This E-Mon DMon meter model must be installed indoors, in an area that is free NOTE: Refer to the Wiring Diagrams, for further information on current sensor. Main Power and Sensor Wiring Diagrams Section Line Voltage / Current Sensor Diagrams. 13 Device description: Emon Dmon Energy Meter.

E

Section 5.4 Main power & sensor wiring diagrams 13 Section 5.5 Line voltage/current sensor diagnostics 14 Section 5.6 RS-485 wiring 15 Section 5.7 Modem wiring 16 Section 6.0 Confi guring the meter using E-Mon Energy™ 17 Section 7.0 Preventative/scheduled maintenance 17

E

Page 14: Mains Line Voltage & Current Sensor Wiring CLASS 2000 METER 4.4 MAINS Line Voltage & Current Sensor Wiring Diagrams CURRENT SENSORS LINE VOLTAGE 3-PHASE, 4-WIRE INSTALLATION DIAGRAM NOTES: LINE VOLTAGE CONNECTIONS: #14-12 AWG SENSOR CONNECTIONS: B = BLACK LEAD W = WHITE LEAD NEUTRAL NOT USED IN DELTA SYSTEM.

E

The E-Mon D-Mon® Class 3000 meter is a 3-element meter with communica-tions. The device is used to monitor electric power usage of individual loads after the utility meter and store kW and kVAR data for automatic meter reading. Installation must only be performed by qualified personnel and in accordance

62

Class 2000 meter without a protective earth ground connection securely installed. 3. Wire Entry. a. Two openings exist on the unit enclosure, one for 1/2” conduit and one for 3/4” conduit. The 3/4” conduit opening located on the bottom of the enclosure is used to bring in MAINS Power (voltage lines to power meter) and current sensor wiring.

62

Class 1000 meter without a protective earth ground connection securely installed. STEP 3: Wire Entry: Two openings exist on the unit enclosure, one for 1/2” conduit and one for 3/4” conduit. The 3/4” conduit opening located on the bottom of the enclosure is used to bring in MAINS Power (voltage lines to power meter) and current sensor wiring.

E

2000 meter without a protective earth ground connection securely installed. 3. Wire Entry. a. Two openings exist on the unit enclosure, one for 1/2” conduit and one for 3/4” conduit. The 3/4” conduit opening located on the bottom of the enclosure is used to bring in MAINS Power (voltage lines to power meter) and current sensor wiring.

Single Phase & Three Phase Wiring Diagrams (1

Room Air Cooler Wiring Diagram # 1; Room Air Cooler Wiring Diagram # 2. (With Capacitor marking and Installation) Wiring of the Distribution Board with RCD , Single Phase, (from Energy Meter to the main Distribution Board) Fuse Board Connection.

Submetering Products

Comprehensive line of leading-edge submeters, communication products and submetering software solutions as the key building blocks to help you better manage costs and conserve energy.

Copyright 2020 - All Rights Reserved